DOCUMENT:Q179398 16-JAN-1998 [vbwin] TITLE :HOWTO: Subclass a UserControl PRODUCT :Microsoft Visual Basic for Windows PROD/VER:WINDOWS:5.0 OPER/SYS:WINDOWS KEYWORDS:vb5all vb5howto ====================================================================== --------------------------------------------------------------------- The information in this article applies to: - Microsoft Visual Basic Control Creation, Professional, and Enterprise Editions for Windows, version 5.0 --------------------------------------------------------------------- SUMMARY ======= In Windows programming terminology, subclassing is the process of creating a message handling procedure to intercept messages for a given window, handling those messages, and passing any remaining messages to the window's original message handler. This article demonstrates how to subclass a UserControl in Visual Basic using the AddressOf operator. MORE INFORMATION ================ In Visual Basic 5.0, the AddressOf operator is used to specify which function in a code module (.BAS file) will be the message handling procedure. The subclass procedure is basically a message filter that performs non-default processing for a few key messages, and passes other messages to a default window procedure using CallWindowProc API. The CallWindowProc API function passes a message to the Windows system, which, in turn, sends the message to the specified window procedure. When subclassing a UserControl with the AddressOf operator, you must take into account that multiple instances of the control utilize the same code module and its functions. In order for the UserControl to maintain its "own" message handling function, the common procedure in the module needs to forward the messages to the proper instance of the UserControl. To implement a function for each instance of a UserControl, you need to create a function in the UserControl to process the messages. The current requirement of Visual Basic 5.0 is that the AddressOf operator can only be used for functions residing in a .BAS module. Therefore, the function in the .BAS module must forward the message to the correct instance of the UserControl. Subclassing using the AddressOf operator is very efficient, but makes debugging a project difficult. If the window you are subclassing receives a message when you are in break mode, Visual Basic will crash. The DBGWPROC.DLL (Debug Object for AddressOf Subclassing) enables you to debug normally while a subclass is active without adding any unnecessary overhead to your finished product or distributing an extra component. This file is available from the Visual Basic Owner's Area at the following location; http://www.microsoft.com/vstudio/owner/ Although it is not necessary, you may want to obtain the Debug Object for AddressOf Subclassing from the Owners Area before proceeding. The following steps show how to create a UserControl that detects mouse activation at design-time and run-time. WARNING: ANY USE BY YOU OF THE CODE PROVIDED IN THIS ARTICLE IS AT YOUR OWN RISK. Microsoft provides this code "as is" without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability and/or fitness for a particular purpose. WARNING: Failure to unhook a window before its imminent destruction will result in application errors, Invalid Page Faults, and data loss. This is due the fact that the new WindowProc function being pointed to no longer exists, but the window has not been notified of the change. Always unhook the sub-classed window upon unloading the sub-classed UserControl or exiting the application. This is especially important while debugging an application that uses this technique within the Microsoft Visual Basic 5.0 Development Environment. Pressing the End button or selecting End from the Run menu without unhooking will cause an Invalid Page Fault and close Microsoft Visual Basic. Step-by-Step Example -------------------- 1. Start Visual Basic 5.0 and create a new ActiveX Control Project. "UserControl1" is created by default. 2. Add the following code to the UserControl1 code module: Option Explicit 'mWndProcOrg holds the original address of the 'Window Procedure for this window. This is used to 'route messages to the original procedure after you 'process them. Private mWndProcOrg As Long 'Handle (hWnd) of the subclassed window. Private mHWndSubClassed As Long 'Constant for Windows Message used in sample. Private Const WM_MOUSEACTIVATE = &H21 Private Sub SubClass() '------------------------------------------------------------- 'Initiates the subclassing of this UserControl's window (hwnd). 'Records the original WinProc of the window in mWndProcOrg. 'Places a pointer to the object in the window's UserData area. '------------------------------------------------------------- 'Exit if the window is already subclassed. If mWndProcOrg Then Exit Sub 'Redirect the window's messages from this control's default 'Window Procedure to the SubWndProc function in your .BAS 'module and record the address of the previous Window 'Procedure for this window in mWndProcOrg. mWndProcOrg = SetWindowLong(hWnd, GWL_WNDPROC, _ AddressOf SubWndProc) 'Record your window handle in case SetWindowLong gave you a 'new one. You will need this handle so that you can unsubclass. mHWndSubClassed = hWnd 'Store a pointer to this object in the UserData section of 'this window that will be used later to get the pointer to 'the control based on the handle (hwnd) of the window getting 'the message. Call SetWindowLong(hWnd, GWL_USERDATA, ObjPtr(Me)) End Sub Private Sub UnSubClass() '----------------------------------------------------------- 'Unsubclasses this UserControl's window (hwnd), setting the 'address of the Windows Procedure back to the address it was 'at before it was subclassed. '----------------------------------------------------------- 'Ensures that you don't try to unsubclass the window when 'it is not subclassed. If mWndProcOrg = 0 Then Exit Sub 'Reset the window's function back to the original address. SetWindowLong mHWndSubClassed, GWL_WNDPROC, mWndProcOrg '0 Indicates that you are no longer subclassed. mWndProcOrg = 0 End Sub Friend Function WindowProc(ByVal hWnd As Long, _ ByVal uMsg As Long, ByVal wParam As Long, _ ByVal lParam As Long) As Long '-------------------------------------------------------------- 'Process the window's messages that are sent to your UserControl. 'The WindowProc function is declared as a "Friend" function so 'that the .BAS module can call the function but the function 'cannot be seen from outside the UserControl project. '-------------------------------------------------------------- 'Start Demo Code: Changes the color of the UserControl each 'time the control is clicked in design-time from red to blue 'or from blue to red. If uMsg = WM_MOUSEACTIVATE Then If UserControl.BackColor = vbRed Then UserControl.BackColor = vbBlue Else UserControl.BackColor = vbRed End If End If 'End Demo Code. 'Forwards the window's messages that came in to the original 'Window Procedure that handles the messages and returns 'the result back to the SubWndProc function. WindowProc = CallWindowProc(mWndProcOrg, hWnd, _ uMsg, wParam, ByVal lParam) End Function Private Sub UserControl_Initialize() 'Occurs the first time a UserControl is placed on a container. UserControl.BackColor = vbRed SubClass End Sub Private Sub UserControl_Terminate() UnSubClass End Sub 3. Add new Standard Module (.BAS) to the project and add the following code: Option Explicit 'API Declarations used for subclassing. Public Declare Sub CopyMemory _ Lib "kernel32" Alias "RtlMoveMemory" _ (pDest As Any, _ pSrc As Any, _ ByVal ByteLen As Long) Public Declare Function SetWindowLong _ Lib "user32" Alias "SetWindowLongA" _ (ByVal hWnd As Long, _ ByVal nIndex As Long, _ ByVal dwNewLong As Long) As Long Public Declare Function GetWindowLong _ Lib "user32" Alias "GetWindowLongA" _ (ByVal hWnd As Long, _ ByVal nIndex As Long) As Long Public Declare Function CallWindowProc _ Lib "user32" Alias "CallWindowProcA" _ (ByVal lpPrevWndFunc As Long, _ ByVal hWnd As Long, _ ByVal Msg As Long, _ ByVal wParam As Long, _ ByVal lParam As Long) As Long 'Constants for GetWindowLong() and SetWindowLong() API's. Public Const GWL_WNDPROC = (-4) Public Const GWL_USERDATA = (-21) 'Used to hold a reference to the control to call its procedure. 'NOTE: "UserControl1" is the UserControl.Name Property at ' design-time of the .CTL file. ' ('As Object' or 'As Control' does not work) Dim ctlShadowControl As UserControl1 'Used as a pointer to the UserData section of a window. Dim ptrObject As Long 'The address of this function is used for subclassing. 'Messages will be sent here and then forwarded to the 'UserControl's WindowProc function. The HWND determines 'to which control the message is sent. Public Function SubWndProc( _ ByVal hWnd As Long, _ ByVal Msg As Long, _ ByVal wParam As Long, _ ByVal lParam As Long) As Long On Error Resume Next 'Get pointer to the control's VTable from the 'window's UserData section. The VTable is an internal 'structure that contains pointers to the methods and 'properties of the control. ptrObject = GetWindowLong(hWnd, GWL_USERDATA) 'Copy the memory that points to the VTable of our original 'control to the shadow copy of the control you use to 'call the original control's WindowProc Function. 'This way, when you call the method of the shadow control, 'you are actually calling the original controls' method. CopyMemory ctlShadowControl, ptrObject, 4 'Call the WindowProc function in the instance of the UserControl. SubWndProc = ctlShadowControl.WindowProc(hWnd, Msg, _ wParam, lParam) 'Destroy the Shadow Control Copy CopyMemory ctlShadowControl, 0&, 4 Set ctlShadowControl = Nothing End Function NOTE: If your UserControl is not named UserControl1, you need to change the "Dim ctlControl As UserControl1" line of code to indicate the correct name of your UserControl as specified by its Name property. 4. Close all the project windows that may be open and save the project. NOTE: During subclassing, you do not want to stop the executing code or it will cause an exception. Always save your project before testing any subclassing code. 5. From the File menu, select "Add Project..." and add a Standard EXE project. This will be your test project. It is named Project2 by default. 6. Open the default form (Form1) of Project2 and place an instance of the UserControl on the form. It should appear as a red rectangle. 7. Each time the mouse is clicked on the UserControl, it should toggle its color between red and blue. 8. Place a second instance of the UserControl on the form. Note that the subclassing works independently on each control, sending the messages to the appropriate control. REFERENCES ========== "Visual Basic 5.0 Programmer's Guide to the Win32 API", by Dan Appleman, published by Ziff-Davis Press, 1997 The Win32 SDK Online Help For additional information, please see the following articles in the Microsoft Knowledge Base: ARTICLE-ID: Q168795 TITLE : HOWTO: Hook Into a Window's Messages Using AddressOf ARTICLE-ID: Q170570 TITLE : HOWTO: Build a Windows Message Handler with AddressOf in VB5 (c) Microsoft Corporation 1998, All Rights Reserved. Contributions by Mike Dixon, Microsoft Corporation ====================================================================== Keywords : vb5all vb5howto Version : WINDOWS:5.0 Platform : WINDOWS Issue type : kbhowto ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 1998.